A: Yes, simply set P0 = U (Voltmeter mode). The relay will remain inactive and the module will just display voltage.
(also known as HCW-M631) is a DC 6-40V battery charge/discharge control module that features an integrated voltmeter and programmable protection modes. 1. Specifications Input Voltage Range: Voltage Accuracy: Relay Output: Typically rated for 10A. Control Modes:
Increase the difference between the lower (U₁) and upper (U₂) voltage settings to prevent "chattering" (rapid on/off cycles). 6. Important Safety Warnings
The is a versatile, digital battery charge and discharge control module . It functions as a programmable voltage switch to protect batteries from overcharging and deep discharging. This comprehensive guide covers specifications, wiring configurations, programming steps, and troubleshooting. 1. Technical Specifications Xh-m608 Manual
: Three micro-switches labeled SET , + (ADD) , and - (DEC) drive the menu logic. Terminal Wiring & System Configurations
In this mode, the module acts as an automatic battery charger switch.
The XH-M608 is an invaluable tool for any project involving DC batteries, offering a perfect blend of advanced protection and user-friendly operation. It serves as a vigilant sentinel, providing automatic, programmable overvoltage and undervoltage protection for 6-40V battery systems. By following the safety instructions and step-by-step guides outlined in this article, you can confidently set up, configure, and deploy the XH-M608 for all your charging and discharging needs. A: Yes, simply set P0 = U (Voltmeter mode)
Release the buttons. The module is now reset to factory defaults. Setting the Mode and Voltage Limits
range. It features an integrated digital voltmeter and a programmable relay to prevent overcharging or deep discharging. Technical Specifications Operating Voltage: DC 6V – 40V Voltage Accuracy: Max Switching Current: Dimensions: 66 x 46 x 17 mm 3-digit LED digital tube Operating Modes (P0 Settings)
This is where the XH-M608 becomes a magician. Leave the jumper on: the relay coil and the logic circuit share the same 5V power – simple, for beginners. the relay disconnects the load
Note: The module uses a high-side switch. The Relay terminals break the connection to the positive side of the charger or load. 3. Programming Instructions (Setting the Parameters) uses a simple "Set", "Add" (+), "Decrease" (-) interface. A. Setting the Low Voltage Protection (Stop Discharge)
Manually verify the current battery voltage against your saved P2 and P3 settings. To help refine your setup, tell me:
Programming the XH-M608 involves selecting the mode and setting the target voltages. Factory Reset
: Connect the XH-M608 between the 12V battery and the 12V load. Set P1 to 10.8V and P2 to 14.4V. The relay stays ON as long as voltage is within the safe range. If the battery drops to 10.8V, the relay disconnects the load, preventing deep discharge.