Circutor Computer 8d96 Manual Full _verified_ Online
The "8D96" designation in its name refers to its physical size—a 96x96mm panel-mount form factor. The full name of the device is , and it is a power factor regulator. Its primary function is to measure the power factor (cos φ) of an electrical network and automatically connect or disconnect capacitor banks to correct it.
Connect to two phases (usually L2 and L3) if utilizing a 400V network, or Phase and Neutral for a 230V network.
Regularly check for heat damage on the output relay terminals.
The regulator is designed for panel mounting with a standard cutout of 96x96 mm. Insert the unit from the front of the panel and secure it using the provided side fixing clips. Wiring Terminal Configurations circutor computer 8d96 manual full
: Never disconnect the current transformer secondary while it is under load without first short-circuiting it, as it can cause lethal overvoltages.
| Parameter | Typical Range / Note | |---|---| | Voltage measurement | 57–690 V L-L depending on model | | Current input (CT) | 1 A or 5 A CT secondary | | Frequency | 45–65 Hz | | Accuracy class | e.g., 0.5s / 1.0 (model dependent) | | Communication | RS-485 Modbus RTU; optional Ethernet |
The Circutor Computer 8d-96 is a robust and intelligent solution for maintaining a high power factor, reducing energy losses, and ensuring the longevity of your electrical equipment. Whether you are an electrical engineer, a maintenance technician, or a facility manager, having access to its full manual is essential for a successful installation and operation. The "8D96" designation in its name refers to
When the device encounters abnormal network conditions or internal system issues, it displays specific error sequences on the screen. Display Code Probable Cause Corrective Action No current detected in measurement terminals.
With these details, I can provide the exact or wiring solutions for your installation.
The front panel typically features four navigation buttons: Connect to two phases (usually L2 and L3)
Built to Category III standards (EN 61010) with double insulation (Class II). Technical Specifications Panel Size 96 x 96 mm (Cut-out: 92x92 mm) Supply Voltage 110V, 230V, 400V, or 480V AC ( Current Input .../5A AC transformer input Operating Temp -10°C to +50°C Output Relays Up to 8 relays (Maximum 250V / 6A) Configuration & Installation
Before installation, verify that your electrical system parameters align with the hardware limits of the device. Specification 230V AC or 400V AC (+10% / -15%), 50/60 Hz Current Measurement Input Transformer ratio input ( In / 5A ) Measurement Range 0.1A to 5A AC Output Relays Max 8 channels, 4A / 250V AC Accuracy Class 1% for voltage and current, 2% for power factor IP Rating Front panel IP54, rear casing IP20 Operating Temperature -10°C to +50°C 3. Wiring and Mechanical Installation
Up to 8 relay outputs for capacitor control. Output Relay Capacity: Max 4 A, 250 V AC.