The background spectrum measures the instrument's response without a sample. It will be ratioed against the sample spectrum to produce a transmittance or absorbance spectrum:

OMNIC includes powerful search algorithms that compare your unknown spectrum against extensive reference libraries. The software can search built-in libraries (such as Hummel and NIST collections) or user-created libraries. Search results include match quality indices to help you identify unknown compounds with confidence. omnic 9 software manual

The manual references ASTM E1655-17 standards for IR quantitative analysis, including tests for:

The Thermo Fisher Scientific OMNIC 9 software is a powerful, user-friendly platform for Fourier Transform Infrared (FTIR) spectroscopy, widely recognized as an industry standard for spectral data acquisition, processing, and analysis. It is a versatile solution, designed for use with Thermo Fisher Scientific's line of FTIR spectrometers, providing users with comprehensive tools for analyzing IR, Raman, and UV-Vis spectroscopy data. As the essential interface between the user and the spectrometer, OMNIC 9 simplifies the complexities of spectroscopic analysis through an intuitive Windows-based environment that supports multitasking, enabling simultaneous measurement and spectrum processing.

The you are analyzing (e.g., polymers, liquid solutions, powders) : Open the files and double-click the setup

Omnic 9’s Macro language is Visual Basic for Applications (VBA)-like. The manual provides syntax for:

OMNIC 9 is designed for Windows environments, historically running on Windows XP and Windows 7, with newer service packs like v9.8 supporting Windows 10 (64-bit) . Recommended hardware includes an Intel Core i5 processor, 8 GB of RAM, and at least 2 GB of disk space. Installation Process:

The option works within the operating system's security environment to address regulatory compliance requirements for laboratories that must follow government regulations regarding data integrity and system validation. When DS is installed and a user signs a file, the software writes a temporary file to the target folder; ensure adequate disk space is available. The software can search built-in libraries (such as

Before data collection, configure your experiment parameters:

for the X-axis and Absorbance or %Transmittance for the Y-axis). 3. Configuring Experiment Parameters

For technical support, contact your local Thermo Fisher Scientific representative or visit the Thermo Fisher Scientific support website at .

: Double-click the program icon. If security features are enabled (e.g., DS option), you will be prompted for a username or password. Experiment Configuration Navigate to Collect -> Experiment Setup