This represents the German national standard ( Deutsches Institut für Normung ) that governs the electroplating of zinc coatings on iron and steel. While newer international standards (like ISO 2081) have largely superseded it, DIN 50961 remains widely referenced in legacy drawings and European manufacturing chains.
Raw zinc coatings are highly reactive and will rapidly develop zinc corrosion (commonly known as "white rust") when exposed to atmospheric moisture. To prevent this, parts undergo a post-plating chemical treatment called passivation.
48 to 72 hours (corrosion of the underlying iron/steel substrate).
DIN 50961 Fe/Zn 8B is a well-defined, legacy technical specification for a "zinc electroplating with a blue chromate conversion coating, 8 µm thick on steel." While older in origin, understanding this code is vital for interpreting legacy designs and for maintaining production continuity. However, for any new product development or design revision, the responsible engineering approach is to transition to the modern framework, specifying current, environmentally compliant coating systems (e.g., using a Zn/8 passivation with a trivalent passivate). This ensures full compliance with modern quality, safety, and environmental standards while achieving the required levels of corrosion protection. din 50961 fe zn 8b
) to comply with environmental regulations like RoHS, replacing the older, toxic Hexavalent ( Cr6+cap C r raised to the 6 plus power ) versions. 4. Compare with modern standards
HV). This can cause sudden, catastrophic brittle failure under tensile stress. For these critical components, DIN 50961 necessitates a post-plating baking process (hydrogen de-embrittlement) within a specified timeframe after plating. Common Industrial Applications
When specifying DIN 50961 Fe/Zn 8B on engineering drawings, use the designation . Additional specification information should include the required load severity level (concerning corrosion resistance) as specified in Clause 7 of the standard, the standard number, and the coating metal. This represents the German national standard ( Deutsches
: The supplementary treatment, typically signifying a chromate conversion coating (passivation) that appears bright or bluish in color. Key Technical Review Din 50961 Fe Zn 8b - Google Groups
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
The table below outlines the different passivation types specified in DIN 50961: To prevent this, parts undergo a post-plating chemical
Indoor switchboxes, trunking, and computer chassis components.
Typically occurs after 48 to 72 hours of continuous salt spray exposure.
Switchboxes, chassis components, and internal mounting plates for electronics.